* Estimated delivery times start from the date of shipment, excluding processing time.
* Actual delivery times may vary due to holidays, weather conditions, or customs delays.
Terugkeer items sal aanvaar word binne 40 dae wanneer dit die datum van ontvangs van die goedere is. Aangepaste items kan nie teruggegee of omgeruil word nie. Items gekoop met 'n e-geskenkbewys is slegs omruilbaar; terugbetalings is nie van toepassing nie.
Gratis Geskenk
Welkom by Roymall, jou professionele webwerf vir die aankoop van premium afdelingswinkel geskenke. Ons waardeer en waardeer jou ondersteuning, en ons wil ons dankbaarheid toon deur 'n ekstra tikkie opwinding by jou aankope te voeg. Wanneer jy by ons shop, kry jy nie net hoë gehalte produkte wat jou lewenstyl verbeter nie, maar jy sal ook 'n eksklusiewe gratis geskenk met elke bestelling wat jy plaas ontvang. Gereed om ons versameling te verken en jou perfekte geskenke te vind? Blaai deur ons keuse van premium afdelingswinkel items, plaas jou bestelling, en sien uit na die opwinding van jou gratis geskenk wat saam met jou aankoop aankom.
Gestuurbeleid
Ons sal hard werk om items aan u te lewer nadat u bestellings ontvang het en sorg dat hulle veilig aankom. Afleweringsbesonderhede sal in u bevestigings-e-pos verskyn.In die meeste gevalle word bestellings binne 2 dae verwerk.Onder spesiale omstandighede sal dit soos volg vertraag: Wanneer u 'n bestelling plaas op Saterdag, Sondag of openbare vakansiedae, sal dit met 2 dae vertraag word.Normaalweg benodig dit 5-7 werksdae (Maandag tot Vrydag) sonder om deur vlugvertraging of ander omgewingsfaktore beïnvloed te word.Omdat ons versending wêreldwyd is, sal die afleveringstye van u ligging afhang, so dit mag 'n paar keer neem en wag asseblief geduldig as u in afgeleë distrikte of lande is.
1. Terugkeer & Omruilingsbeleid
Ons aanvaar slegs items wat van roymall.com gekoop is. As u by ons plaaslike verspreiders of ander kleinhandelaars koop, kan u dit nie aan ons kant teruggee nie.Finale verkoop items of gratis geskenke is nie aanvaarbaar vir 'n terugkeer nie.Om in aanmerking te kom vir 'n terugkeer, moet u item ongebruik en in dieselfde toestand wees as wat u dit ontvang het. Dit moet ook in die oorspronklike verpakking wees.Nadat u terugkeerinstruksies van ons ontvang het, verpak asseblief u teruggekeerde items en los u pakkie by die plaaslike poskantoor of 'n ander koerier.Ons sal u terugkeer of omruilingsitem binne 3-5 werksdae verwerk nadat ons dit ontvang het. Die terugbetaling sal verwerk en outomaties aan u oorspronklike betaalmetode gekrediteer word.Geen teruggawes of omruilings kan aanvaar word as die produk op maat vervaardig is, insluitend pasgemaakte grootte, pasgemaakte kleur of pasgemaakte druk nie.Het u meer hulp nodig, kontak ons asseblief. service@roymall.com of Whatsapp: +8619359849471
2.Terugbetalingsbeleid
U sal 'n volledige terugbetaling of 100% winkelkrediet ontvang nadat ons die teruggekeerde pakkie ontvang en nagegaan het. Die terugbetaling sal verwerk en outomaties aan u oorspronklike betaalmetode gekrediteer word.Let asseblief daarop dat gestuurkoste en enige regte of fooie nie terugbetaalbaar is nie. Die ekstra gestuurkoste is nie terugbetaalbaar sodra die pakkie gestuur is nie. U is verantwoordelik om hierdie fooie te betaal en ons is nie in staat om dit te laat vaar of terug te betaal nie, selfs as die bestelling aan ons terugbesorg word.Sodra ons u teruggekeerde item ontvang en bevestig het, sal ons 'n e-pos aan u stuur om u te laat weet dat ons u teruggekeerde item ontvang het. Ons sal u ook in kennis stel van die goedkeuring of verwerping van u terugbetaling.As u enige probleme met betrekking tot die terugbetalingsproses het, kontak ons asseblief. service@roymall.com of Whatsapp: +8619359849471
20A DC Digital Multifunction Power Meter Energy Monitor Module Voltmeter Ammeter 6.5V-100V
Description:
Working Voltage
DC 6.5V-100V
Measuring Voltage
DC 6.5V-100V
Measuring Voltage
0-20A
Rated Power
2000W
Display
LCD
Display Format
Power
0.0-999.9W (<1KW)
1000-2000w(>1KW)
Energy
0-999Wh(<10KWh)
10-9999KWh(>10KWh)
Voltage
6.50-99.99V
Current
0.00-20.00A
Feature: - 20A DC multifunction power meter - LCD display wih backlight, easy to read - Bult-in shunt design, no extra needed - Power, current, voltage and energy display and monitor timely , easy to know electric energy consumption - Electric energy clear function, perfect for various device monitor separately
- Overload alarm function (over power alarm threshold, the backlight and voltage flashing alarm) - Power memory, shave the power parameter when power down, safe to use
Operaqtion Tips:
1. The backlight control
By short press the button to turn on or off the backlight, In the bakclight mode,the data will automatically store when power down
2. The energy cleared
Step 1: Press the power button 5 seconds until the digital display "CLr" , then release the button;
Step 2: Now it is in the "energy clear" mode, press the button again, the energy data is cleared and stop flashing;
Step 3: If in the "energy clear" mode you do not press the button in 5 seconds,then the energy data will not be cleared
3. Set power alarm value
Step 1: Press the button, when the power area display "SET ", release button,
Step 2:it is in the pweor alarming setting mode, the voltage area displays the highest value of the voltage alarm,the current area displays the lowest value of the voltage alarm. Then you can press the button quickly to increase the value" +1", when there is no key operation more than three seconds,
It happens that this power meter may give incorrect readings (more than should be). It can be calibrated by opening up the back and shorting the pads marked "W" on the PCB, then add 20V to the input and 1A load (20 Ohms) to the output. Then power on, wait for the display say "Pass" then power off and remove the short. Ta-daa: calibrated.
It happens that this power meter may give incorrect readings (more than should be). It can be calibrated by opening up the back and shorting the pads marked "W" on the PCB, then add 20V to the input and 1A load (20 Ohms) to the output. Then power on, wait for the display say "Pass" then power off and remove the short. Ta-daa: calibrated.
It happens that this power meter may give incorrect readings (more than should be). It can be calibrated by opening up the back and shorting the pads marked "W" on the PCB, then add 20V to the input and 1A load (20 Ohms) to the output. Then power on, wait for the display say "Pass" then power off and remove the short. Ta-daa: calibrated.
I did a whole bunch of looking around for a supply monitor for my power supply I am building. This one seemed great but the minimum 6.5V input meant I could not supply lower voltages. Upon reading the reviews I found one detailing that removing the diode "D" and placing the power monitor supply positive lead on the cathode (part of the diode with the line on it). allowed for lower voltages to be measured. So I tried it and it worked! Just tweaked the alarm trigger to 0V and now it works great!
I did a whole bunch of looking around for a supply monitor for my power supply I am building. This one seemed great but the minimum 6.5V input meant I could not supply lower voltages. Upon reading the reviews I found one detailing that removing the diode "D" and placing the power monitor supply positive lead on the cathode (part of the diode with the line on it). allowed for lower voltages to be measured. So I tried it and it worked! Just tweaked the alarm trigger to 0V and now it works great!
I did a whole bunch of looking around for a supply monitor for my power supply I am building. This one seemed great but the minimum 6.5V input meant I could not supply lower voltages. Upon reading the reviews I found one detailing that removing the diode "D" and placing the power monitor supply positive lead on the cathode (part of the diode with the line on it). allowed for lower voltages to be measured. So I tried it and it worked! Just tweaked the alarm trigger to 0V and now it works great!
Tips:For questions about your order, place of delivery, product discount, taxation, delivery time, warranty, shipping, payment, exchange rate, and other questions unrelated to the product, please contact customer service.
you too??
ordered mine March 10...still nothing as of April 19th.
you too??
ordered mine March 10...still nothing as of April 19th.
Answered by jsdavis55 on 20/04/2019Helpful (0)
0
Q:
Hello, The load part of the device was short-circuited and the shunt resistance between the negative connections inside was burnt. Does any one know the value of this resistance?
Regards //Turkish
Hey, hey,
The load part of the device was short-circuited and the shunt resistance between the internal negative connections burned. Does anyone know the value of this resistance?
Regards
Hello, The load part of the device was short-circuited and the shunt resistance between the negative connections inside was burned. Does anyone know the value of this resistance?
Regards //Türkish
Selam,
Cihazın yük kısmı kısa devre oldu ve içteki negatif bağlantılar arasındaki şönt direnç yandı. Bu direncin değerini bilen var mı?
Saygılar
hellocan you be more specific are you able to provide the R number or part number you are looking to replace, if that is not possible take a photograph of the damaged area and send it to me and I will see what I can do.as follow up if the parts you are refering to are R3
hellocan you be more specific are you able to provide the R number or part number you are looking to replace, if that is not possible take a photograph of the damaged area and send it to me and I will see what I can do.as follow up if the parts you are refering to are R3
Answered by clazh on 24/04/2020Helpful (0)
0
Q:
I bought this , received but want to seek help in connecting it.
I want to monitor a solar panel banks of 48VDC, do i need to get another 12V, input for the meter or what do i need to do to enable me use this meter to monitor the solar panels output volatge of 48VDC
I bought this , received but want to seek help in connecting it.
I want to monitor a solar panel banks of 48VDC, do i need to get another 12V, input for the meter or what do i need to do to enable me use this meter to monitor the solar panels output volatge of 48VDC
can i measure solar power with this i have 1 kva solar panels installed and connected to inverter
so i want to use this meter to connect inbetween solar and inverter to maesure current and voltage?
how
can i measure solar power with this i have 1 kva solar panels installed and connected to inverter
so i want to use this meter to connect inbetween solar and inverter to maesure current and voltage?
how
Hi Vaibhavkumar Birajdar, yes you could use this power meter. But be aware that you stay within it's parameters!...
Hi Vaibhavkumar Birajdar, yes you could use this power meter. But be aware that you stay within it's parameters!...
Answered by armin on 21/11/2019Helpful (0)
0
Q:
In case someone don't know, this instrument can be calibrated for precise measurements. For this, you need a power supply set to 20V and a 20 Ohm resistor connected to the Load terminals. Use thick and short cabling. Remove the back cover, and find the two empty jumper holes in the corner opposite to the connector terminals marked "W". Temporarily short this, then connect the power supply. The display says "CAL" then "PASS", release the power. The instrument is now calibrated. Make a test measurement, correct the voltage if necessary (if after calibration meter shows more than should, raise calibration voltage, calibrate again)
In case someone don't know, this instrument can be calibrated for precise measurements. For this, you need a power supply set to 20V and a 20 Ohm resistor connected to the Load terminals. Use thick and short cabling. Remove the back cover, and find the two empty jumper holes in the corner opposite to the connector terminals marked "W". Temporarily short this, then connect the power supply. The display says "CAL" then "PASS", release the power. The instrument is now calibrated. Make a test measurement, correct the voltage if necessary (if after calibration meter shows more than should, raise calibration voltage, calibrate again)
Common positive, the current measuring shunt is between the negative lines.
Common positive, the current measuring shunt is between the negative lines.
Answered by Aurum on 02/06/2019Helpful (0)
0
Q:
Hello banggod I have bught this meter but i have no idea how to use I want to measure the amount of power from the car headlight bulb How to right way to connect the wire to make it run correct
Hello banggod I have bught this meter but i have no idea how to use I want to measure the amount of power from the car headlight bulb How to right way to connect the wire to make it run correct
This meter only measures up to 100V DC. You could theoretically use a voltage divider circuit to give only 1/3 of your voltage to the meter. It would only show a value up to 100V but you just need to multiply it by 3 to get your total voltage.
This meter only measures up to 100V DC. You could theoretically use a voltage divider circuit to give only 1/3 of your voltage to the meter. It would only show a value up to 100V but you just need to multiply it by 3 to get your total voltage.
Answered by Fluvance on 04/11/2018Helpful (0)
Ask a Question
1.You can contact the customer service. for any question regarding the product.
2.Ask the question in English to get answer faster.